mx-dio-ctl
Moxa DIO Control
mx-dio-ctl
is a common script for controlling DIO's interface mode
Source Code Link
Support Model
Prerequisite
Before use mx-dio-ctl
script, you should install drivers as below.
Usage
mx-dio-ctl <-i|-o <#port number> [-s <#state>]>
- Get value from DIN port 0
mx-dio-ctl -i 0
- Get value from DOUT port 0
mx-dio-ctl -o 0
- Set DOUT port 0 value to LOW
mx-dio-ctl -o 0 -s 0
- Set DOUT port 0 value to HIGH
mx-dio-ctl -o 0 -s 1
Model IO Table
DA-820C
6 DIs and 2 DOs on the rear panel
DIO Port Number DI 0 DI 1 DI 2 DI 3 DI 4 DI 5 DO 0 DO 1
DA-682C
6 DIs and 2 DOs on the rear panel
DIO Port Number DI 0 DI 1 DI 2 DI 3 DI 4 DI 5 DO 0 DO 1
DA-681C
6 DIs and 2 DOs on the rear panel
DIO Port Number DI 0 DI 1 DI 2 DI 3 DI 4 DI 5 DO 0 DO 1
V2403C
4 DIs and 4 DOs on the rear panel
DIO Port Number DI 0 DI 1 DI 2 DI 3 DO 0 DO 1 DO 2 DO 3
V2201
4 DIs and 4 DOs on the left side
DIO Port Number DI 0 DI 1 DI 2 DI 3 DO 0 DO 1 DO 2 DO 3
V3000
2 DIs and 2 DOs
DIO Port Number DI 0 DI 1 DO 0 DO 1
DA-680
2 DOs
DIO Port Number DO 0 DO 1
Last updated on 2023-02-15 by Wilson Huang